1. Home
  2. Hollis
  3. Hollis 100LX DC3 Regulator

Hollis

100LX DC3 Regulator

£289.00 RRP £369.00 SKU: 61211-1

Play button Created with Sketch.
Hollis 100LX DC3 Regulator
Hollis 100LX DC3 Regulator Hollis 100LX DC3 Regulator Hollis 100LX DC3 Regulator Hollis 100LX DC3 Regulator Hollis 100LX DC3 Regulator

Hollis
100LX DC3 Regulator

£289.00 RRP £369.00 SKU: 61211-1

Other: DIN 300

Only 1 Left
Created with Sketch. Free UK delivery on orders over £50.00
Add to wishlist
Group 16 Created with Sketch. £

Earn loyalty points

Find out more

Points for this product:

*   equivalent

Details

Features

Delivery / Returns

Reviews

Hollis

100LX DC3 Regulator

£289.00 RRP £369.00

Brand: Hollis

Model: 100LX DC3 Regulator

SKU: 61211-1

Please note: This item cannot be shipped outside the European Union - learn more

The Hollis 100LX DC3 Regulator is the simplest of the LX range with all of the features of the 150 except for the metal front ring and it is paired with the DC3 1st stage. If you're after a simple high-performance set of regs this combination is a great pairing without a large price tag

100LX 2nd Stage

The 100LX 2nd stage has fewer metal parts to make it lighter but it still has the reversible design and adjustable Venturi lever. The reversible design can change the orientation of the hose depending on which side you want the hose to come out from by a Hollis Technician. The Venturi lever changes the direction of the airflow inside the body to prevent freeflows on the surface.

DC3 1st Stage

The DC3 is a compact, environmentally sealed 1st stage with all of the ports you'll need in a simple smart design.

Prescription Lenses

Hollis 100LX DC3 Regulator - Features

FeatureProduct Specification
Adjustable Inhalation
?This feature allows the diver to adjust the inhalation setting from the set level and increase the effort required to open the 2nd stage valve to deliver air.
No
Adjustable Venturi
?The venturi control affects how air flows in the 2nd stage. In it's positive position the flow of gas creates a vacuum against the diapragm, helping to open the valve. In it's negative position it will divert gas back against the diaphragm helping to close the valve. It is basically used to help prevent free flowing.
Yes
Cold Water Rated
?Cold water has adverse effects on regulators and can cause some to freeze so each regulator combination must be tested during manufacturing for their performance in different water temperatures.

Cold water is defined by EN250 as below 10°C. If a regulator combination cannot meet the performance standards below 10°C then they are only suitable for warm waters.


EN250 / (EN250A >10°C)
To pass the regulator must provide at least 62.5 L/min of air at 50M depth above 10°C.
Cold & Warm Water
Environmentally sealed
?Environmentally sealed 1st stages offer greater protection against freezing when diving in cold water (below 10 degrees C)

Scubapro have a new method of cold water proofing their first stages called the eXtended Thermal Insulating System or XTIS which still allows water into the first stage but the internal parts that come into contact with the water are coated to prevent ice from forming.
Yes
First Stage
?Unbalanced regulators are affected by the pressure in the cylinder, becoming slighty harder to breathe from when the pressure starts to drop.

Balanced regulators are not affected by the cylinder pressure or depth.

Over-balanced regulators achieve unprecedented performance by increasing your air supply the deeper you go providing the best breathe for deep divers.
Balanced
High Pressure Ports
?High pressure ports supply the pressure gauge and wireless transmitters for dive computers
2
Low Pressure Ports
?Low pressure ports supply the 2nd stages and inflator hoses
4
Second Stage
?An Unbalanced second stage is simply a lever operated valve that is opened and closed as the diaphragm is pulled inwards by the vacuum that is created when the diver inhales. An unbalanced second stage is affected by increased pressure at depth, slightly increasing the effort required to open the valve.

A Balanced second stage overcomes the effects of increased pressure by utilising a balancing chamber. This chamber takes some of the work away from the spring mechanism, allowing a smaller spring to be used which results in an easier breathe. As the chamber uses air to balance the valve it maintains the same resistance as the diver descends and ascends, keeping the inhalation effort the same.
Balanced
TypeDiaphragm
Weight in Grams (approx)
?The weight includes the first stage (DIN fitting), hose and second stage.
1040

Delivery

We offer free standard delivery on orders over £50. Learn more.

Standard delivery is £3.70 for orders under £50. You will receive your order 2 - 4 days from the date of despatch.

Next Working Day is £6.50.

 

Returns

We hope you will be completely satisfied with any product purchased from Simply Scuba.

However, you can return it for any reason within 28 days from the date of despatch for a full refund (less postage costs).

Customer Reviews

Based on 1 review Write a review

Watch the video

Free UK Delivery

on all orders over £50

Retailer of the Year

Diver Magazine & Sport Diver

5 Star Rating

Customer Feedback

0% Finance Available

On UK Orders Over £400
Top